| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A weakness has been identified in bestfeng oa_git_free up to 9.5. This affects the function updateWriteBack of the file yimioa-oa9.5\server\c-flow\src\main\java\com\cloudweb\oa\controller\WorkflowPredefineController.java. This manipulation of the argument writeProp causes xml external entity reference. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited. |
| Mercku M6a devices through 2.1.0 allow root TELNET logins via the web admin password. |
| The password reset mechanism for the Pivot client application is weak, and it may allow an attacker to take over the account. |
| New Site Server developed by CyberTutor has a Use of Client-Side Authentication vulnerability, allowing unauthenticated remote attackers to modify the frontend code to gain administrator privileges on the website. |
| CWE-601: URL Redirection to Untrusted Site ('Open Redirect') |
| Protection mechanism failure in some 3rd, 4th, and 5th Generation Intel(R) Xeon(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. |
| An Insecure Direct Object Reference (IDOR) vulnerability exists in the vehicleId parameter, allowing unauthorized access to sensitive information of other users’ vehicles. Exploiting this issue enables an attacker to retrieve data such as GPS coordinates, encryption keys, initialization vectors, model numbers, and fuel statistics belonging to other users, instead of being limited to their own vehicle data. The fix for this vulnerability is a server-side authorization fix. |
| A vulnerability has been found in Union Bank of India Vyom 8.0.34 on Android and classified as problematic. This vulnerability affects unknown code of the component Rooting Detection. The manipulation leads to protection mechanism failure. The attack needs to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Certain motherboard models developed by GIGABYTE has a Protection Mechanism Failure vulnerability. Because IOMMU was not properly enabled, unauthenticated physical attackers can use a DMA-capable PCIe device to read and write arbitrary physical memory before the OS kernel and its security features are loaded. |
| A security vulnerability has been detected in CloudPanel Community Edition up to 2.5.1. The affected element is an unknown function of the file /admin/users of the component HTTP Header Handler. Such manipulation of the argument Referer leads to open redirect. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used. Upgrading to version 2.5.2 is sufficient to fix this issue. Upgrading the affected component is recommended. |
| An Open Redirect vulnerability in the go-chi/chi >=5.2.2 RedirectSlashes function allows remote attackers to redirect victim users to malicious websites using the legitimate website domain. |
| A low privileged remote attacker can upload arbitrary data masked as a png file to the affected device using the webserver API because only the file extension is verified. |
| tar-fs provides filesystem bindings for tar-stream. Versions prior to 3.1.1, 2.1.3, and 1.16.5 are vulnerable to symlink validation bypass if the destination directory is predictable with a specific tarball. This issue has been patched in version 3.1.1, 2.1.4, and 1.16.6. A workaround involves using the ignore option on non files/directories. |
| LinuxServer.io Heimdall before 2.5.7 does not prevent use of icons that have non-image data such as the "<?php ?>" substring. |
| Astro is a web framework for content-driven websites. Following CVE-2025-54793 there's still an Open Redirect vulnerability in a subset of Astro deployment scenarios prior to version 9.4.1. Astro 5.12.8 addressed CVE-2025-54793 where https://example.com//astro.build/press would redirect to the external origin //astro.build/press. However, with the Node deployment adapter in standalone mode and trailingSlash set to "always" in the Astro configuration, https://example.com//astro.build/press still redirects to //astro.build/press. This affects any user who clicks on a specially crafted link pointing to the affected domain. Since the domain appears legitimate, victims may be tricked into trusting the redirected page, leading to possible credential theft, malware distribution, or other phishing-related attacks. This issue has been patched in version 9.4.1. |
| When the module renders a Svg file that contains a <pattern> element, it might end up rendering it recursively leading to stack overflow DoS |
| SOCA Access Control System 180612 contains multiple insecure direct object reference vulnerabilities that allow attackers to access sensitive user credentials. Attackers can retrieve authenticated and unauthenticated user password hashes and pins through unprotected endpoints like Get_Permissions_From_DB.php and Ac10_ReadSortCard. |
| An unauthenticated attacker with access to TCP port 12306 of the WorkExaminer server can exploit missing server-side authentication checks to bypass the login prompt in the WorkExaminer Professional console to gain administrative access to the WorkExaminer server and therefore all sensitive monitoring data. This includes monitored screenshots and keystrokes of all users.
The WorkExaminer Professional console is used for administrative access to the server. Before access to the console is granted administrators must login. Internally, a custom protocol is used to call a respective stored procedure on the MSSQL database. The return value of the call is not validated on the server-side. Instead it is only validated client-side which allows to bypass authentication. |
| An issue in Orban Optimod 5950, Optimod 5950HD, Optimod 5750, Optimod 5750HD, Optimod Trio Optimod version 1.0.0.33 - System version 2.5.26 allows a remote attacker to escalate privileges via the application stores user privilege/role information in client-side browser storage |
| Overly Restrictive Account Lockout Mechanism vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series allows a remote unauthenticated attacker to lockout legitimate users for a certain period by repeatedly attempting to login with incorrect passwords. The legitimate users will be unable to login until a certain period has passed after the lockout or until the product is reset. |