| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices. |
| An issue in H3C Magic M Device M2V100R006 allows a remote attacker to execute arbitrary code via the default password |
| A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs. |
| The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges. |
| Use of hard-coded, the same among all vulnerable installations SQLite credentials vulnerability in SIGNUM-NET FARA allows to read and manipulate local-stored database.This issue affects FARA: through 5.0.80.34. |
| Iridium Certus 700 version 1.0.1 has an embedded credentials vulnerability in the code. This vulnerability allows a local user to retrieve the SSH hash string. |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| In Optigo Networks ONS NC600 versions 4.2.1-084 through 4.7.2-330, an attacker could connect with the device's ssh server and utilize the system's components to perform OS command executions. |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| luci-app-lucky v2.8.3 was discovered to contain hardcoded credentials. |
| Shenzhen Tuoshi NR500-EA RG500UEAABxCOMSLICv3.4.2731.16.43 devices enable the SSH service by default. There is a hidden hard-coded root account that cannot be disabled in the GUI. |
| FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system. |
| In the IROAD APK 5.2.5, there are Hardcoded Credentials in the APK for ports 9091 and 9092. The mobile application for the dashcam contains hardcoded credentials that allow an attacker on the local Wi-Fi network to access API endpoints and retrieve sensitive device information, including live and recorded footage. |
| Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) contains hardcoded API credentials and an OS command injection flaw in its configuration services. The web/API interface accepts HTTP/XML requests authenticated with a fixed vendor credential string and passes user-controlled fields into shell execution contexts without proper argument sanitization. An unauthenticated remote attacker can leverage the hard-coded credential to access endpoints such as /editBlackAndWhiteList and inject shell metacharacters inside XML parameters, resulting in arbitrary command execution as root. The same vulnerable backend is also reachable in some models through a proprietary TCP service on port 4567 that accepts a magic GUID preface and base64-encoded XML, enabling the same command injection sink. Firmware releases from mid-February 2018 and later are reported to have addressed this issue. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-28 UTC. |
| The ArchiverSpaApi ASP.NET application uses a hard-coded JWT signing key. An unauthenticated remote attacker can generate and use a verifiable JWT token to access protected ArchiverSpaApi URL endpoints. |
| Ubiquiti U7-Pro 7.0.35 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: this is disputed by the Supplier because the observation only established that a password is present in a firmware image; however, the device cannot be deployed without setting a new password during installation. |
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. |
| An RPC service, which is part of exos 9300, is reachable on port 4000, run by the process FSMobilePhoneInterface.exe. This service is used for interprocess communication between services and the Kaba exos 9300 GUI, containing status information about the Access Managers. Interacting with the service does not require any authentication. Therefore, it is possible to send arbitrary status information about door contacts etc. without prior authentication. |
| Precor touchscreen console P62, P80, and P82 could allow a remote attacker to obtain sensitive information because the root password is stored in /etc/passwd. An attacker could exploit this to extract files and obtain sensitive information. |