| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects all Iocharger AC EV charger models on a firmware version before 25010801.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.
This issue affects Iocharger firmware for AC models before firmware version 25010801.
The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.
Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.
Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| SAP NetWeaver AS for Java allows an authorized attacker to obtain sensitive information. The attacker could obtain the username and password when creating an RFC destination. After successful exploitation, an attacker can read the sensitive information but cannot modify or delete the data. |
| A flaw was found in grub2 where the grub_extcmd_dispatcher() function calls grub_arg_list_alloc() to allocate memory for the grub's argument list. However, it fails to check in case the memory allocation fails. Once the allocation fails, a NULL point will be processed by the parse_option() function, leading grub to crash or, in some rare scenarios, corrupt the IVT data. |
| SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data. |
| SAP GUI for Windows may allow the leak of NTML hashes when specific ABAP frontend services are called with UNC paths. For a successful attack, the attacker needs developer authorization in a specific Application Server ABAP to make changes in the code, and the victim needs to execute by using SAP GUI for Windows. This could trigger automatic NTLM authentication, potentially exposing hashed credentials to an attacker. As a result, it has a high impact on the confidentiality. |
| BrightSign players running BrightSign OS series 4 prior to v8.5.53.1 or
series 5 prior to v9.0.166 contain an execution with unnecessary
privileges vulnerability, allowing for privilege escalation on the
device once code execution has been obtained. |
| A vulnerability was identified in SUR-FBD CMMS where hard-coded credentials were found within a compiled DLL file. These credentials correspond to a built-in administrative account of the software. An attacker with local access to the system or the application's installation directory could extract these credentials, potentially leading to a complete compromise of the application's administrative functions. This issue was fixed in version 2025.03.27 of the SUR-FBD CMMS software. |
| A vulnerability in the web API of HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to terminate arbitrary running processes. Successful exploitation could allow an attacker to disrupt system operations, potentially resulting in an unstable system state. |
| The SSH service of PowerStation from HGiga has a Chroot Escape vulnerability, allowing attackers with root privileges to bypass chroot restrictions and access the entire file system. |
| Attackers with local access to the medical office computer can
escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by
overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is
writable for all users. In addition, the Elefant installer registers two
Firebird database services which are running as “NT AUTHORITY\SYSTEM”.
Path: C:\Elefant1\Firebird_2\bin\fbserver.exe
Path: C:\Elefant1\Firebird_2\bin\fbguard.exe
Both service binaries are user writable. This means that a local
attacker can rename one of the service binaries, replace the service
executable with a new executable, and then restart the system. Once the
system has rebooted, the new service binary is executed as "NT
AUTHORITY\SYSTEM". |
| A flaw was found in openshift/builder. This vulnerability allows command injection via path traversal, where a malicious user can execute arbitrary commands on the OpenShift node running the builder container. When using the “Docker” strategy, executable files inside the privileged build container can be overridden using the `spec.source.secrets.secret.destinationDir` attribute of the `BuildConfig` definition. An attacker running code in a privileged container could escalate their permissions on the node running the container. |
| A security vulnerability in HCL Compass can allow attacker to gain unauthorized database access. |
| A potential vulnerability was reported in some Lenovo Tablets that could allow a local authenticated user or application to gain access to sensitive device specific information. |
| Toshiba printers use SNMP for configuration. Using the private community, it is possible to remotely execute commands as root on the remote printer. Using this vulnerability will allow any attacker to get a root access on a remote Toshiba printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |