| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| OpenMQ exposes a TCP-based management service (imqbrokerd) that by default requires
authentication. However, the product ships with a default administrative account (admin/
admin) and does not enforce a mandatory password change on first use. After the first
successful login, the server continues to accept the default password indefinitely without
warning or enforcement.
In real-world deployments, this service is often left enabled without changing the default
credentials. As a result, a remote attacker with access to the service port could authenticate
as an administrator and gain full control of the protocol’s administrative features. |
| Istio is an open platform to connect, manage, and secure microservices. Prior to 1.29.1, 1.28.5, and 1.27.8, a user of Istio is impacted if the JWKS resolver becomes unavailable or the fetch fails, exposing hardcoded defaults regardless of use of the RequestAuthentication resource. This vulnerability is fixed in 1.29.1, 1.28.5, and 1.27.8. |
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. |
| Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF contains an authentication credentials leakage vulnerability.This issue affects Hitachi Ops Center Common Services: from 10.0.0-00 before 11.0.0-04; Hitachi Ops Center Analyzer viewpoint OVF: from 10.0.0-00 before 11.0.0-04. |
| MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials. |
| BrightSign players running BrightSign OS series 4 prior to v8.5.53.1 or
series 5 prior to v9.0.166 use a default password that is guessable with
knowledge of the device information. The latest release fixes this
issue for new installations; users of old installations are encouraged
to change all default passwords. |
| All the Toshiba printers share the same hardcoded root password. As for the affected products/models/versions, see the reference URL. |
| If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface
protected by authentication. If the default credentials are not changed,
an attacker can use public knowledge to access the device as an
administrator. |
| nginx-defender is a high-performance, enterprise-grade Web Application Firewall (WAF) and threat detection system engineered for modern web infrastructure. This is a configuration vulnerability affecting nginx-defender deployments. Example configuration files
config.yaml and docker-compose.yml contain default credentials (default_password: "change_me_please", GF_SECURITY_ADMIN_PASSWORD=admin123). If users deploy nginx-defender without changing these defaults, attackers with network access could gain administrative control, bypassing security protections. The issue is addressed in v1.5.0 and later. |
| By default, the password for the Access Manager's web interface, is set to 'admin'. In the tested version changing the password was not enforced. |
| A vulnerability was identified in TRENDnet TI-G160i, TI-PG102i and TPL-430AP up to 20250724. This affects an unknown part of the component SSH Service. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The vendor explains: "For product TI-PG102i and TI-G160i, by default, the product's remote management options are all disabled. The root account is for troubleshooting purpose and the password is encrypted. However, we will remove the root account from the next firmware release. For product TPL-430AP, the initial setup process requires user to set the password for the management GUI. Once that was done, the default password will be invalid." |
| IO-1020 Micro ELD uses a default WIFI password that could allow an adjacent attacker to connect to the device.
|
| Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 use weak default credentials for secure shell access. This may result in attackers gaining access to exposed Gardyn Home Kits. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
| COMMAX CVD-Axx DVR 5.1.4 contains weak default administrative credentials that allow remote password attacks and disclose RTSP stream. Attackers can exploit this by sending a POST request with the 'passkey' parameter set to '1234', allowing them to access the web control panel. |
| Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics
Solution is only in scope of
this vulnerability when
installed on a NUC server. BD Synapsys™
Informatics Solution installed
on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is
not in scope. |
| A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credentials. A remote attacker capable of interacting with the FTP server could gain access and perform changes over resources exposed by the service such as configuration files where password hashes are saved or where network settings are stored. |
| A vulnerability in the Eclipse Vert.x toolkit causes a memory leak in TCP servers configured with TLS and SNI support. When processing an unknown SNI server name assigned the default certificate instead of a mapped certificate, the SSL context is erroneously cached in the server name map, leading to memory exhaustion. This flaw allows attackers to send TLS client hello messages with fake server names, triggering a JVM out-of-memory error. |
| IO-1020 Micro ELD web server uses a default password for authentication.
|
| Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA.
This issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.3-00; Hitachi Ops Center OVA: from 10.9.3-00 before 11.0.2-01. |