| An Uncontrolled Search Path Element issue was discovered in AzeoTech DAQFactory versions prior to 17.1. An uncontrolled search path element vulnerability has been identified, which may execute malicious DLL files that have been placed within the search path. |
| An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL. |
| Untrusted search path vulnerability in NFC Port Software remover Ver.1.3.0.1 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Untrusted search path vulnerability in PatchJGD (PatchJGD101.EXE) ver. 1.0.1 allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| A vulnerability in the Cisco FindIT Network Discovery Utility could allow an authenticated, local attacker to perform a DLL preloading attack, potentially causing a partial impact to the device availability, confidentiality, and integrity, aka Insecure Library Loading. The vulnerability is due to the application loading a malicious copy of a specific, nondefined DLL file instead of the DLL file it was expecting. An attacker could exploit this vulnerability by placing an affected DLL within the search path of the host system. An exploit could allow the attacker to load a malicious DLL file into the system, thus partially compromising confidentiality, integrity, and availability on the device. Cisco Bug IDs: CSCvf37955. |
| Untrusted search path vulnerability in LhaForge Ver.1.6.5 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Microsoft Skype 7.16.0.102 contains a vulnerability that could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system. This vulnerability exists due to the way .dll files are loaded by Skype. It allows an attacker to load a .dll of the attacker's choosing that could execute arbitrary code without the user's knowledge.The specific flaw exists within the handling of DLL (api-ms-win-core-winrt-string-l1-1-0.dll) loading by the Skype.exe process. |
| Audacity 2.1.2 through 2.3.2 is vulnerable to Dll HIjacking in the avformat-55.dll resulting arbitrary code execution. |
| mcmnm in BMC Patrol allows local users to gain privileges via a crafted libmcmclnx.so file in the current working directory, because it is setuid root and the RPATH variable begins with the .: substring. |
| An Uncontrolled Search Path or Element issue was discovered in i-SENS SmartLog Diabetes Management Software, Version 2.4.0 and prior versions. An uncontrolled search path element vulnerability has been identified which could be exploited by placing a specially crafted DLL file in the search path. If the malicious DLL is loaded prior to the valid DLL, an attacker could execute arbitrary code on the system. This vulnerability does not affect the connected blood glucose monitor and would not impact delivery of therapy to the patient. |
| In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application. |
| In EMC VNX2 versions prior to OE for File 8.1.9.211 and VNX1 versions prior to OE for File 7.1.80.8, a local authenticated user can load a maliciously crafted file in the search path which may potentially allow the attacker to execute arbitrary code on the targeted VNX Control Station system, aka an uncontrolled search path vulnerability. |
| A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges. |
| DLL Hijacking vulnerability in CorelDRAW X7, Corel Photo-Paint X7, Corel PaintShop Pro X7, Corel Painter 2015, and Corel PDF Fusion. |
| An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file. |
| An Uncontrolled Search Path Element issue was discovered in Trihedral VTScada 11.3.03 and prior. The program will execute specially crafted malicious dll files placed on the target machine. |
| If HashiCorp Vagrant VMware Fusion plugin (aka vagrant-vmware-fusion) 5.0.3 is installed but VMware Fusion is not, a local attacker can create a fake application directory and exploit the suid sudo helper in order to escalate to root. |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls Heating Control Downloader (HCDownloader) Version 1.0.1.15 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls WATTConfig M Software Version 2.5.10.1 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. |
| An Uncontrolled Search Path Element issue was discovered in SIMPlight SCADA Software version 4.3.0.27 and prior. The uncontrolled search path element vulnerability has been identified, which may allow an attacker to place a malicious DLL file within the search path resulting in execution of arbitrary code. |