| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| setuid() does not affect libuv's internal io_uring operations if initialized before the call to setuid().
This allows the process to perform privileged operations despite presumably having dropped such privileges through a call to setuid().
This vulnerability affects all users using version greater or equal than Node.js 18.18.0, Node.js 20.4.0 and Node.js 21. |
| A vulnerability in the web API of HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to terminate arbitrary running processes. Successful exploitation could allow an attacker to disrupt system operations, potentially resulting in an unstable system state. |
| A vulnerability exists in the VideONet product included in the listed System 800xA versions, where VideONet is used.
An attacker who successfully exploited the vulnerability could, in the worst case scenario, stop or manipulate the video feed.
This issue affects System 800xA: 5.1.X; System 800xA: 6.0.3.X; System 800xA: 6.1.1.X; System 800xA: 6.2.X. |
| Unchecked return value in SDM firmware for Intel(R) Stratix 10 and Intel(R) Agilex 7 FPGAs before version 23.3 may allow an authenticated user to potentially enable denial of service via adjacent access. |
| Toshiba printers use SNMP for configuration. Using the private community, it is possible to remotely execute commands as root on the remote printer. Using this vulnerability will allow any attacker to get a root access on a remote Toshiba printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS. |
| The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| A vulnerability was found in SGAI Space1 NAS N1211DS up to 1.0.915. This issue affects the function GET_FACTORY_INFO/GET_USER_INFO of the file /cgi-bin/JSONAPI of the component gsaiagent. The manipulation results in unprotected storage of credentials. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The Toshiba printers are vulnerable to a Local Privilege Escalation vulnerability. An attacker can remotely compromise any Toshiba printer. As for the affected products/models/versions, see the reference URL. |
| The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| Toshiba printers contain hardcoded credentials. As for the affected products/models/versions, see the reference URL. |
| Coredump binaries in Toshiba printers have incorrect permissions. A local attacker can steal confidential information. As for the affected products/models/versions, see the reference URL. |
| The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified. |
| A vulnerability was found in BlackVue App 3.65 on Android and classified as problematic. Affected by this issue is some unknown functionality of the component API Endpoint Handler. The manipulation of the argument BCS_TOKEN/SECRET_KEY leads to unprotected storage of credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| In BootROM, there is a possible missing validation for Certificate Type 0. This could lead to local escalation of privilege with no additional execution privileges needed. |
| Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0. |
| Draytek devices Vigor 165/166 prior to v4.2.6 , Vigor 2620/LTE200 prior to v3.9.8.8, Vigor 2860/2925 prior to v3.9.7, Vigor 2862/2926 prior to v3.9.9.4, Vigor 2133/2762/2832 prior to v3.9.8, Vigor 2135/2765/2766 prior to v4.4.5.1, Vigor 2865/2866/2927 prior to v4.4.5.3, Vigor 2962/3910 prior to v4.3.2.7, Vigor 3912 prior to v4.3.5.2, and Vigor 2925 up to v3.9.6 were discovered to store passwords in plaintext. |
| The access control in CemiPark software stores integration (e.g. FTP or SIP) credentials in plain-text. An attacker who gained unauthorized access to the device can retrieve clear text passwords used by the system.This issue affects CemiPark software: 4.5, 4.7, 5.03 and potentially others. The vendor refused to provide the specific range of affected products.
|
| BAS-IP AV-01D, AV-01MD, AV-01MFD, AV-01ED, AV-01KD, AV-01BD, AV-01KBD, AV-02D, AV-02IDE, AV-02IDR, AV-02IPD, AV-02FDE, AV-02FDR, AV-03D, AV-03BD, AV-04AFD, AV-04ASD, AV-04FD, AV-04SD, AV-05FD, AV-05SD, AA-07BD, AA-07BDI, BA-04BD, BA-04MD, BA-08BD, BA-08MD, BA-12BD, BA-12MD, CR-02BD before firmware v3.9.2 allows authenticated attackers to read SIP account passwords via a crafted GET request. |