| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A security issue exists within the 5032 16pt Digital Configurable module’s web server. Intercepted session credentials can be used within a 3-minute timeout window, allowing unauthorized users to perform privileged actions. |
| Incorrect access control in Shenzhen Tuoshi Network Communications Co.,Ltd 5G CPE Router NR500-EA RG500UEAABxCOMSLICv3.2.2543.12.18 allows attackers to access the SSH protocol without authentication. |
| A vulnerability was found in Mercusys MW301R 1.0.2 Build 190726 Rel.59423n. It has been rated as problematic. This issue affects some unknown processing of the component Login. The manipulation leads to improper restriction of excessive authentication attempts. The attack can only be initiated within the local network. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| Missing Authentication for Critical Function, Improper Access Control vulnerability in Dinosoft Business Solutions Dinosoft ERP allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects Dinosoft ERP: from < 3.0.1 through 11022026.
NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14. |
| Authorization Bypass Through User-Controlled Key, Weak Password Recovery Mechanism for Forgotten Password, Authentication Bypass by Assumed-Immutable Data vulnerability in Optimus Software Brokerage Automation allows Exploiting Trust in Client, Authentication Bypass, Manipulate Registry Information.This issue affects Brokerage Automation: before 1.1.71. |
| TSA developed by Changing has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents. |
| FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal camera video feeds across multiple camera series without requiring any authentication. |
| A vulnerability exists in Snap One OVRC cloud where an attacker can impersonate a Hub device and send requests to claim and unclaim devices. The attacker only needs to provide the MAC address of the targeted device and can make a request to unclaim it from its original connection and make a request to claim it. |
| Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .
All firmware versions with the Serial Number from 2000 to 5166 |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to manipulate the device via a specific functionality. |
| GALAYOU G2 cameras stream video output via RTSP streams. By default these streams are protected by randomly generated credentials. However these credentials are not required to access the stream. Changing these values does not change camera's behavior.
The vendor did not respond in any way. Only version 11.100001.01.28 was tested, other versions might also be vulnerable. |
| Authentication Bypass by Primary Weakness vulnerability in XPodas Octopod allows Authentication Bypass.This issue affects Octopod: before v1.
NOTE: The vendor was contacted and it was learned that the product is not supported.
|
| Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device. |
| KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages. |
| A vulnerability was found in Digistar AG-30 Plus 2.6b. It has been classified as problematic. Affected is an unknown function of the component Login Page. The manipulation leads to improper restriction of excessive authentication attempts. The complexity of an attack is rather high. The exploitability is told to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| Selea CarPlateServer 4.0.1.6 contains a remote program execution vulnerability that allows attackers to execute arbitrary Windows binaries by manipulating the NO_LIST_EXE_PATH configuration parameter. Attackers can bypass authentication through the /cps/ endpoint and modify server configuration, including changing admin passwords and executing system commands. |
| An unauthenticated attacker with access to the local network of the
medical office can query an unprotected Fast Healthcare Interoperability
Resources (FHIR) API to get access to sensitive electronic health
records (EHR). |
| The web application allows an unauthenticated remote attacker to learn information about existing user accounts with their corresponding role due to missing authentication for critical function. |