Export limit exceeded: 351286 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (2183 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-40628 | 2026-04-15 | N/A | ||
| SQL injection vulnerability in DomainsPRO 1.2. This vulnerability could allow an attacker to retrieve, create, update and delete databases via the “d” parameter in the “/article.php” endpoint. | ||||
| CVE-2025-40634 | 1 Tp-link | 1 Archer Ax50 | 2026-04-15 | N/A |
| Stack-based buffer overflow vulnerability in the 'conn-indicator' binary running as root on the TP-Link Archer AX50 router, in firmware versions prior to 1.0.15 build 241203 rel61480. This vulnerability allows an attacker to execute arbitrary code on the device over LAN and WAN networks. | ||||
| CVE-2025-40635 | 2026-04-15 | N/A | ||
| SQL injection vulnerability in Comerzzia Backoffice: Sales Orchestrator 3.0.15. This vulnerability allows an attacker to retrieve, create, update and delete databases via the ‘uidActivity’, ‘codCompany’ and ‘uidInstance’ parameters of the ‘/comerzzia/login’ endpoint. | ||||
| CVE-2025-40636 | 1 Joomla | 3 Joomla, Joomla!, Mod Vvisit Counter | 2026-04-15 | N/A |
| SQL injection vulnerability in Joomla module mod_vvisit_counter v2.0.4j3. This vulnerability allows an attacker to retrieve database content via the ‘cip_vvisitcounter’ cookie at all endpoints where the plugin counts visits. | ||||
| CVE-2025-40671 | 2026-04-15 | N/A | ||
| SQL injection vulnerability in AES Multimedia's Gestnet v1.07. This vulnerability allows an attacker to retrieve, create, update and delete databases via the ‘fk_remoto_central’ parameter on the ‘/webservices/articles.php’ endpoint. | ||||
| CVE-2025-40771 | 1 Siemens | 6 Simatic Cp 1542sp-1, Simatic Cp 1542sp-1 Irc, Simatic Cp 1543sp-1 and 3 more | 2026-04-15 | 9.8 Critical |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. | ||||
| CVE-2025-4009 | 2026-04-15 | N/A | ||
| The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz. This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365). CVE-2025-4009 covers the command injection in feature-transfer-import.php CVE-2025-10364 covers the command injection in feature-transfer-export.php Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices. This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others. | ||||
| CVE-2025-3463 | 2026-04-15 | N/A | ||
| "This issue is limited to motherboards and does not affect laptops, desktop computers, or other endpoints." An insufficient validation vulnerability in ASUS DriverHub may allow untrusted sources to affect system behavior via crafted HTTP requests. Refer to the 'Security Update for ASUS DriverHub' section on the ASUS Security Advisory for more information. | ||||
| CVE-2025-3476 | 2026-04-15 | N/A | ||
| Incorrect Authorization vulnerability in OpenText™ Operations Bridge Manager. The vulnerability could allows privilege escalation by authenticated users.This issue affects Operations Bridge Manager: 2023.05, 23.4, 24.2, 24.4. | ||||
| CVE-2025-3578 | 2026-04-15 | N/A | ||
| A malicious, authenticated user in Aidex, versions prior to 1.7, could list credentials of other users, create or modify existing users in the application, list credentials of users in production or development environments. In addition, it would be possible to cause bugs that would result in the exfiltration of sensitive information, such as details about the software or internal system paths. These actions could be carried out through the misuse of LLM Prompt (chatbot) technology, via the /api/<string-chat>/message endpoint, by manipulating the contents of the ‘content’ parameter. | ||||
| CVE-2025-3579 | 2026-04-15 | N/A | ||
| In versions prior to Aidex 1.7, an authenticated malicious user, taking advantage of an open registry, could execute unauthorised commands within the system. This includes executing operating system (Unix) commands, interacting with internal services such as PHP or MySQL, and even invoking native functions of the framework used, such as Laravel or Symfony. This execution is achieved by Prompt Injection attacks through the /api/<string-chat>/message endpoint, manipulating the content of the ‘content’ parameter. | ||||
| CVE-2025-3621 | 2026-04-15 | 9.6 Critical | ||
| Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems. * vulnerabilities: * Improper Neutralization of Special Elements used in a Command ('Command Injection') * Use of Hard-coded Credentials * Improper Authentication * Binding to an Unrestricted IP Address The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required. | ||||
| CVE-2025-3651 | 2026-04-15 | N/A | ||
| Improper Verification of Source of a Communication Channel in Work Desktop for Mac versions 10.8.1.46 and earlier allows attackers to execute arbitrary commands via unauthorized access to the Agent service. This has been remediated in Work Desktop for Mac version 10.8.2.33. | ||||
| CVE-2025-36535 | 1 Automationdirect | 1 Mb Gateway | 2026-04-15 | 10 Critical |
| The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality. | ||||
| CVE-2025-3659 | 2026-04-15 | N/A | ||
| Improper authentication handling was identified in a set of HTTP POST requests affecting the following product families: * Digi PortServer TS - prior to and including 82000747_AA, build date 06/17/2022 * Digi One SP/Digi One SP IA/Digi One IA - prior to and including 82000774_Z, build date 10/19/2020 * Digi One IAP – prior to and including 82000770 Z, build date 10/19/2020 A specially crafted POST request to the device’s web interface may allow an unauthenticated attacker to modify configuration settings. | ||||
| CVE-2025-36751 | 1 Growatt | 2 Mic3300tl-x, Shinelan-x | 2026-04-15 | N/A |
| Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint. | ||||
| CVE-2025-36754 | 1 Growatt | 1 Shinelan-x | 2026-04-15 | N/A |
| The authentication mechanism on web interface is not properly implemented. It is possible to bypass authentication checks by crafting a post request with new settings since there is no session token or authentication in place. This would allow an attacker for instance to point the device to an arbitrary address for domain name resolution to e.g. facililitate a man-in-the-middle (MitM) attack. | ||||
| CVE-2025-36852 | 2 Niklas Portmann, Nx | 7 Nx-remotecache-azure, Nx-remotecache-custom, Nx-remotecache-minio and 4 more | 2026-04-15 | N/A |
| A critical security vulnerability exists in remote cache extensions for common build systems utilizing bucket-based remote cache (such as those using Amazon S3, Google Cloud Storage, or similar object storage) that allows any contributor with pull request privileges to inject compromised artifacts from an untrusted environment into trusted production environments without detection. The vulnerability exploits a fundamental design flaw in the "first-to-cache wins" principle, where artifacts built in untrusted environments (feature branches, pull requests) can poison the cache used by trusted environments (protected branches, production deployments). This attack bypasses all traditional security measures including encryption, access controls, and checksum validation because the poisoning occurs during the artifact construction phase, before any security measures are applied. | ||||
| CVE-2025-3710 | 2026-04-15 | 9.8 Critical | ||
| The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device. | ||||
| CVE-2025-3711 | 2026-04-15 | 9.8 Critical | ||
| The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device. | ||||