| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The passwordless login mechanism in CGFIDO from Changing Information Technology has an Authentication Bypass vulnerability, allowing remote attackers with regular privileges to send a crafted request to switch to the identity of any user, including administrators. |
|
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that
could cause account takeover and unauthorized access to the system when an attacker
conducts brute-force attacks against the login form.
|
| An unauthenticated remote attacker can gain access to the cloud API due to a lack of authentication for a critical function in the affected devices. Availability is not affected. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| Peppermint Ticket Management 0.4.6 is vulnerable to Incorrect Access Control. A regular registered user is able to elevate his privileges to admin and gain complete access to the system as the authorization mechanism is not validated on the server side and only on the client side. This can result, for example, in creating a new admin user in the system which enables persistent access for the attacker as an administrator. |
| Incorrect access control in the fingerprint authentication mechanism of Bitdefender Mobile Security v4.11.3-gms allows attackers to bypass fingerprint authentication due to the use of a deprecated API. |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes. |
| Certain Anpviz products allow unauthenticated users to modify or disable camera related settings such as microphone volume, speaker volume, LED lighting, NTP, motion detection, etc. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera. |
| Remote Control Server, maintained by Steppschuh, 3.1.1.12 allows unauthenticated remote code execution when authentication is disabled, which is the default configuration. The server exposes a custom UDP-based control protocol that accepts remote keyboard input events without verification. An attacker on the same network can issue a sequence of keystroke commands to launch a system shell and execute arbitrary commands, resulting in full system compromise. |
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). Affected devices allow a remote authenticated user or an unauthenticated user with physical access to downgrade the firmware of the device. This could allow an attacker to downgrade the device to older versions with known vulnerabilities. |
| An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function. |
| A vulnerability classified as problematic was found in Lucky LM-520-SC, LM-520-FSC and LM-520-FSC-SAM up to 20250321. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A low privileged remote attacker may modify the configuration of the CODESYS V3 service through a missing authentication vulnerability which could lead to full system access and/or DoS. |
| A unauthorized access vulnerability exists in the Xiaomi phone framework. The vulnerability is caused by improper validation and can be exploited by attackers to Access sensitive methods. |
| A Missing Authentication for Critical Function vulnerability in the GRUB configuration used B&R APROL <4.4-01 may allow an unauthenticated physical attacker to alter the boot configuration of the operating system. |
| A lack of rate limiting in the OTP validation component of Digitory Multi Channel Integrated POS v1.0 allows attackers to gain access to the ordering system and place an excessive amount of food orders. |
| PutongOJ is online judging software. Prior to version 2.1.0-beta.1, unprivileged users can escalate privileges by constructing requests. This can lead to unauthorized access, enabling users to perform admin-level operations, potentially compromising sensitive data and system integrity. This problem has been fixed in v2.1.0.beta.1. As a workaround, one may apply the patch from commit `211dfe9` manually. |
| The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| Sensitive data disclosure and manipulation due to missing authentication. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 39870, Acronis Cyber Protect 16 (Linux, macOS, Windows) before build 39938, Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 41800. |