| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| APKF Product Key Finder 2.5.8.0 contains a denial of service vulnerability that allows attackers to crash the application by overflowing the 'Name' input field. Attackers can generate a 1000-character payload and paste it into the registration name field to trigger an application crash. |
| Buffer Overflow vulnerability in NEXTU FLATA AX1500 Router v.1.0.2 allows a remote attacker to execute arbitrary code via the POST request handler component. |
| Heap-based Buffer Overflow, Memory Corruption, Out-Of-Bounds Read, Out-Of-Bounds Write, Stack-based Buffer Overflow, Type Confusion, Uninitialized Variable, Use-After-Free vulnerabilities exist in the file reading procedure in SOLIDWORKS Desktop on Release SOLIDWORKS 2024.
These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted CATPART, DWG, DXF, IPT, JT, SAT, SLDDRW, SLDPRT, STL, STP, X_B or X_T file. |
| An issue was discovered in ECCurve.java and ECCurve.cs in Bouncy Castle Java (BC Java) before 1.78, BC Java LTS before 2.73.6, BC-FJA before 1.0.2.5, and BC C# .Net before 2.3.1. Importing an EC certificate with crafted F2m parameters can lead to excessive CPU consumption during the evaluation of the curve parameters. |
| Out-of-bounds Read vulnerability in dail8859 NotepadNext (src/lua/src modules). This vulnerability is associated with program files lparser.C.
This issue affects NotepadNext: through v0.11.
The singlevar() in lparser.c lacks a certain luaK_exp2anyregup call, leading to a heap-based buffer over-read that might affect a system that compiles untrusted Lua code. |
| Amazon AWS Client VPN has a buffer overflow that could potentially allow a local actor to execute arbitrary commands with elevated permissions. This is resolved in 3.11.1 on Windows, 3.9.1 on macOS, and 3.12.1 on Linux. NOTE: although the macOS resolution is the same as for CVE-2024-30165, this vulnerability on macOS is not the same as CVE-2024-30165. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
| wire-ios is an iOS client for the Wire secure messaging application. From Wire iOS 3.111.1 to before 3.124.1, messages that were visible in the view port have been logged to the iOS system logs in clear text. Wire application logs created and managed by the application itself were not affected, especially not the logs users can export and send to Wire support. The iOS logs can only be accessed if someone had (physical) access to the underlying unlocked device. The issue manifested itself by calling canOpenUrl() and passing an invalid URL object. When iOS then performs the check and fails, it logs the contents to the system log. This is not documented behaviour. Wire released an emergency fix with version 3.124.1. As a workaround, users can reset their iOS device to remove the offending logs. Since Wire cannot access or modify iOS system logs, there's no other workaround other than a reset. |
| Use of Default Cryptographic Key vulnerability in Baxter Welch Allyn Connex Spot Monitor may allow Configuration/Environment Manipulation.This issue affects Welch Allyn Connex Spot Monitor in all versions prior to 1.52. |
| A post-authentication format string vulnerability in SonicOS management allows a remote attacker to crash a firewall and potentially leads to code execution. |
| In some cases, the ktrace facility will log the contents of kernel structures to userspace. In one such case, ktrace dumps a variable-sized sockaddr to userspace. There, the full sockaddr is copied, even when it is shorter than the full size. This can result in up to 14 uninitialized bytes of kernel memory being copied out to userspace.
It is possible for an unprivileged userspace program to leak 14 bytes of a kernel heap allocation to userspace. |
| A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credentials. A remote attacker capable of interacting with the FTP server could gain access and perform changes over resources exposed by the service such as configuration files where password hashes are saved or where network settings are stored. |
| A CWE-126 “Buffer Over-read” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The information disclosure can be triggered by leveraging a memory leak affecting the web server. A remote unauthenticated attacker can exploit this vulnerability in order to leak valid authentication tokens from the process memory associated to users currently logged to the system and bypass the authentication mechanism. |
| An issue in @thi.ng/paths v.5.1.62 and before allows a remote attacker to execute arbitrary code via the mutIn and mutInManyUnsafe components. |
| HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may connect to the product via SSH and use a shell. |
| The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device. |
| HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may change the system settings. |
| Xibo is an Open Source Digital Signage platform with a web content management system and Windows display player software. In affected versions some request headers are not correctly sanitised when stored in the session and display tables. These headers can be used to inject a malicious script into the session page to exfiltrate session IDs and User Agents. These session IDs / User Agents can subsequently be used to hijack active sessions. A malicious script can be injected into the display grid to exfiltrate information related to displays. Users should upgrade to version 3.3.10 or 4.0.9 which fix this issue. Customers who host their CMS with the Xibo Signage service have already received an upgrade or patch to resolve this issue regardless of the CMS version that they are running. Upgrading to a fixed version is necessary to remediate. Patches are available for earlier versions of Xibo CMS that are out of security support: 2.3 patch ebeccd000b51f00b9a25f56a2f252d6812ebf850.diff. 1.8 patch a81044e6ccdd92cc967e34c125bd8162432e51bc.diff. There are no known workarounds for this issue. |
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. |
| A Improper Validation of Array Index issue affecting the v2_sdk_service running on a set of DJI drone devices on the port 10000 could allow an attacker to corrupt a controlled memory location due to a missing input validation in the on_receive_session_packet_ack function implemented in the libv2_sdk.so library used by the dji_vtwo_sdk binary implementing the service, potentially leading to a memory information leak or to an arbitrary code execution. Affected models are Mavic 3 Pro until v01.01.0300, Mavic 3 until v01.00.1200, Mavic 3 Classic until v01.00.0500, Mavic 3 Enterprise until v07.01.10.03, Matrice 300 until v57.00.01.00, Matrice M30 until v07.01.0022 and Mini 3 Pro until v01.00.0620. |