| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
|
The APDFL.dll contains a memory corruption vulnerability while parsing
specially crafted PDF files. This could allow an attacker to execute
code in the context of the current process.
|
|
Fuji Electric Tellus Lite V-Simulator versions 4.0.12.0 and prior are vulnerable to an out-of-bounds write which may allow an attacker to execute arbitrary code.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not validate the length of RTLS report payloads during communication. This allows an attacker to send an exceedingly long payload, resulting in an out-of-bounds write to cause a denial-of-service condition or code execution.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the monitor services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the backup services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.
|
|
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior are vulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code or crash the device remotely.
|
| All versions of Landis+Gyr E850 (ZMQ200) are vulnerable to CWE-784: Reliance on Cookies Without Validation and Integrity. The device's web application navigation depends on the value of the session cookie. The web application could become inaccessible for the user if an attacker changes the cookie values.
|
| All versions prior to Delta Electronic’s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.
|
| Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.
|
| Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to an out-of-bounds write, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.
|
| Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.
|
| If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition.
|
|
The Sub-IoT implementation of the DASH 7 Alliance protocol has a vulnerability that can lead to an out-of-bounds write prior to implementation version 0.5.0. If the protocol has been compiled using default settings, this will only grant the attacker access to allocated but unused memory. However, if it was configured using non-default settings, there is the possibility that exploiting this vulnerability could lead to system crashes and remote code execution.
|
| Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP POST parameter called by index.php script. |
| Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts. |
|
Datakit CrossCadWare_x64.dll contains an out-of-bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to execute code in the context of the current process.
|
| Versions of INEA ME RTU firmware prior to 3.36 are vulnerable to OS command injection, which could allow an attacker to remotely execute arbitrary code. |
|
Versions 00.07.00 through 00.07.03 of Teltonika’s RUT router firmware contain an operating system (OS) command injection vulnerability in a Lua service. An attacker could exploit a parameter in the vulnerable function that calls a user-provided package name by instead providing a package with a malicious name that contains an OS command injection payload.
|
| Delta Electronics DIAScreen may write past the end of an allocated
buffer while parsing a specially crafted input file. This could allow an
attacker to execute code in the context of the current process.
|
|
Sante DICOM Viewer Pro lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.
|