| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Zenitel TCIV-3+ is vulnerable to a reflected cross-site scripting
vulnerability, which could allow a remote attacker to execute arbitrary
JavaScript on the victim's browser. |
| An OS command injection vulnerability exists due to incomplete
validation of user-supplied input. Validation fails to enforce
sufficient formatting rules, which could permit attackers to append
arbitrary data. This could allow an unauthenticated attacker to inject
arbitrary commands. |
| An OS command injection vulnerability exists due to insufficient
sanitization of user-supplied input. The application accepts parameters
that are later incorporated into OS commands without adequate
validation. This could allow an unauthenticated attacker to execute
arbitrary commands remotely. |
| SQL injection vulnerability in the IcProgreso Innovación y Cualificación plugin. This vulnerability allows an attacker to obtain, update and delete data from the database by injecting an SQL query on the parameters user, id, idGroup, start_date and end_date in the endpoint /report/icprogreso/generar_blocks.php. |
| Application does not limit the number or frequency of user interactions, such as the number of incoming requests. At the "/EPMUI/VfManager.asmx/ChangePassword" endpoint it is possible to perform a brute force attack on the current password in use.
This issue affects CyberArk Endpoint Privilege Manager in SaaS version 24.7.1. The status of other versions is unknown. After multiple attempts to contact the vendor we did not receive any answer. |
| When the service of ABP and AES is installed in a directory writable by non-administrative users, an attacker can replace or plant a DLL with the same name as one loaded by the service. Upon service restart, the malicious DLL is loaded and executed under the LocalSystem account, resulting in unauthorized code execution with elevated privileges.
This issue affects ABP and AES: from ABP 2.0 through 2.0.7.9050, from AES 1.0 through 1.0.6.8290. |
| Security Point (Windows) of MaLion and MaLionCloud contains a stack-based buffer overflow vulnerability in processing HTTP headers. Receiving a specially crafted request from a remote unauthenticated attacker could lead to arbitrary code execution with SYSTEM privilege. |
| Insufficiently Protected Credentials
vulnerability in OpenText Identity Manager Advanced Edition on Windows, Linux,
64 bit allows Privilege Abuse. This vulnerability could allow an
authenticated user to obtain higher privileged user’s sensitive information via
crafted payload.
This issue affects Identity Manager Advanced
Edition: from 4.8.0.0 through 4.8.7.0102, 4.9.0.0. |
| MinIO is a high-performance, S3 compatible object store, open sourced under GNU AGPLv3 license. Minio is subject to a privilege escalation in IAM import API, all users are impacted since MinIO commit `580d9db85e04f1b63cc2909af50f0ed08afa965f`. This issue has been addressed in commit `f246c9053f9603e610d98439799bdd2a6b293427` which is included in RELEASE.2024-12-13T22-19-12Z. There are no workarounds possible, all users are advised to upgrade immediately. |
| A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.
This could allow an unauthenticated remote attacker to execute arbitrary code. |
| Use of fixed learning codes, one code to lock the car and the other code to unlock it, the Key Fob Transmitter in KIA-branded Aftermarket Generic Smart Keyless Entry System, primarily distributed in Ecuador, which allows a replay attack.
Manufacture is unknown at the time of release. CVE Record will be updated once this is clarified. |
| InnovaStudio WYSIWYG Editor 5.4 contains an unrestricted file upload vulnerability that allows attackers to bypass file extension restrictions through filename manipulation. Attackers can upload malicious ASP shells by using null byte techniques and alternate file extensions to circumvent upload controls in the asset manager. |
| The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface. |
| Wp2Fac 1.0 contains an OS command injection vulnerability in the send.php endpoint that allows remote attackers to execute arbitrary system commands. Attackers can inject shell commands through the 'numara' parameter by appending shell commands with '&' operators to execute malicious code. |
| An authentication-bypass vulnerability exists in AiCloud. This vulnerability can be triggered by an unintended side effect of the Samba functionality, potentially leading to allow execution of specific functions without proper authorization.
Refer to the Security Update for ASUS Router Firmware section on the ASUS Security Advisory for more information. |
| BASIS BBj versions prior to 25.00 contain a Jetty-served web endpoint that fails to properly validate or canonicalize input path segments. This allows unauthenticated directory traversal sequences to cause the server to read arbitrary system files accessible to the account running the service. Retrieved configuration artifacts may contain account credentials used for BBj Enterprise Manager; possession of these credentials enables administrative access and use of legitimate management functionality that can result in execution of system commands under the service account. Depending on the operating system and the privileges of the BBj service account, this issue may also allow access to other sensitive files on the host, including operating system or application data, potentially exposing additional confidential information. |
| Tinycontrol LAN Controller v3 LK3 version 1.58a contains an unauthenticated vulnerability that allows remote attackers to download configuration backup files containing sensitive credentials. Attackers can retrieve the lk3_settings.bin file and extract base64-encoded user and admin passwords without authentication. |
| The server lacks thread safety and can be crashed by anomalous data sent by an anonymous user from a remote network. The crash causes the FTP service to become unavailable, affecting all users and processes that rely on it for file transfers. If the crash occurs during file upload or download, it could lead to incomplete file transfers, potentially corrupting data. The repeated crash might also affect the stability of the underlying system, especially if it leads to resource leaks or affects other services. |
| Smart Parking Management System from Honding Technology has an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to access a specific page and obtain plaintext administrator credentials. |
| The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users with hardcoded and weak passwords that can be used to access the devices via SSH. The passwords can be also guessed very easily. The password of at least one user is set to a random value after the first deployment, with the restriction that the password is only randomized if the configured date is prior to 2022. Therefore, under certain circumstances, the passwords are not randomized. For example, if the clock is never set on the device, the battery of the clock module has been changed, the Access Manager has been factory reset and has not received a time yet. |