| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Unauthorized redirect vulnerability in Citrix NetScaler ADC before 10.1 135.8, 10.5 61.11, 11.0 65.31/65.35F and 11.1 47.14 allows a remote attacker to steal session cookies of a legitimate AAA user via manipulation of Host header. |
| The "lost password" functionality in b2evolution before 6.7.9 allows remote attackers to reset arbitrary user passwords via a crafted request. |
| An issue was discovered in phpMyAdmin. Username matching for the allow/deny rules may result in wrong matches and detection of the username in the rule due to non-constant execution time. All 4.6.x versions (prior to 4.6.5), 4.4.x versions (prior to 4.4.15.9), and 4.0.x versions (prior to 4.0.10.18) are affected. |
| An issue was discovered in phpMyAdmin. With a crafted request parameter value it is possible to bypass the logout timeout. All 4.6.x versions (prior to 4.6.5), and 4.4.x versions (prior to 4.4.15.9) are affected. |
| An issue was discovered in phpMyAdmin. Due to a bug in serialized string parsing, it was possible to bypass the protection offered by PMA_safeUnserialize() function. All 4.6.x versions (prior to 4.6.5), 4.4.x versions (prior to 4.4.15.9), and 4.0.x versions (prior to 4.0.10.18) are affected. |
| GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) "2" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors. |
| GE Healthcare Millennium MG, NC, and MyoSIGHT has a password of insite.genieacq for the insite account that cannot be changed without disabling product functionality for remote InSite support, which has unspecified impact and attack vectors. |
| ZOLL Defibrillator / Monitor M Series, E Series, and R Series have a default password for System Configuration mode, which allows physically proximate attackers to modify device configuration and cause a denial of service (adverse human health effects). |
| GE Healthcare Centricity DMS 4.2, 4.1, and 4.0 has a password of Muse!Admin for the Museadmin user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. |
| GE Healthcare Discovery 530C has a password of #bigguy1 for the (1) acqservice user and (2) wsservice user of the Xeleris System, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. |
| Arris DG860A, TG862A, and TG862G devices with firmware TS0703128_100611 through TS0705125D_031115 have predictable technician passwords, which makes it easier for remote attackers to obtain access via the web management interface, related to a "password of the day" issue. |
| A certain Gentoo patch for the PAM S/Key module does not properly clear credentials from memory, which allows local users to obtain sensitive information by reading system memory. |
| config/.htpasswd in Yealink IP Phone SIP-T38G has a hardcoded password of (1) user (s7C9Cx.rLsWFA) for the user account, (2) admin (uoCbM.VEiKQto) for the admin account, and (3) var (jhl3iZAe./qXM) for the var account, which makes it easier for remote attackers to obtain access via unspecified vectors. |
| The client in IBM Cognos TM1 9.5.2.3 before IF5, 10.1.1.2 before IF1, 10.2.0.2 before IF1, and 10.2.2.0 before IF1 stores obfuscated passwords in memory, which allows remote authenticated users to obtain sensitive cleartext information via an unspecified security tool. |
| IBM SPSS Analytic Server 1.0 before IF002 and 1.0.1 before IF004 logs cleartext passwords, which allows remote authenticated users to obtain sensitive information via unspecified vectors. |
| Jenkins before 1.587 and LTS before 1.580.1 do not properly ensure trust separation between a master and slaves, which might allow remote attackers to execute arbitrary code on the master by leveraging access to the slave. |
| The QuickType feature in the Keyboards subsystem in Apple iOS before 8.1 collects typing-prediction data from fields with an off autocomplete attribute, which makes it easier for attackers to discover credentials by reading credential values within unintended DOM input elements. |
| CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 has a hardcoded application password, which makes it easier for remote authenticated users to obtain application-file access via unspecified vectors. |
| CareFusion Pyxis SupplyStation 8.1 with hardware test tool 1.0.16 and earlier has a hardcoded database password, which makes it easier for local users to gain privileges by leveraging cabinet access. |
| CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 allows local users to obtain potentially sensitive information by reading a temporary (1) debugging file or (2) developer file. |