| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in EasyVista 2020.2.125.3 and 2022.1.109.0.03. Part of the application does not implement protection against brute-force attacks. Version 2022.1.133.0 corrects this issue. |
| Failure to validate addresses provided by software to BIOS commands may result in a potential loss of integrity of guest memory in a confidential compute environment.
|
| The software interfaces to ASP and SMU may not enforce the SNP memory security policy resulting in a potential loss of integrity of guest memory in a confidential compute environment.
|
| The password reset feature of Ai3 QbiBot lacks proper access control, allowing unauthenticated remote attackers to reset any user's password. |
| The authentication mechanism in SonicWall GMS and Analytics Web Services had insufficient checks, allowing authentication bypass. This issue affects GMS: 9.3.2-SP1 and earlier versions; Analytics: 2.5.0.4-R7 and earlier versions. |
| An access control issue in Harbor v1.X.X to v2.5.3 allows attackers to access public and private image repositories without authentication. NOTE: the vendor's position is that this "is clearly described in the documentation as a feature." |
| An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication. |
| NVIDIA BMC IPMI handler allows an unauthenticated host to write to a host SPI flash bypassing secureboot protections. This may lead to a loss of integrity and denial of service. |
| NVIDIA DGX A100 contains a vulnerability in SBIOS in the SmiFlash, where a local user with elevated privileges can read, write and erase flash, which may lead to code execution, escalation of privileges, denial of service, and information disclosure. The scope of impact can extend to other components. |
| NVIDIA DGX Station contains a vulnerability in SBIOS in the SmiFlash, where a local user with elevated privileges can read, write and erase flash, which may lead to code execution, escalation of privileges, denial of service, and information disclosure. The scope of impact can extend to other components. |
| A vulnerability, which was classified as problematic, has been found in codelyfe Stupid Simple CMS 1.2.4. This issue affects some unknown processing of the component Login Page. The manipulation leads to improper restriction of excessive authentication attempts. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The identifier VDB-259049 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| A flaw was found in the openstack-barbican component. This issue allows an access policy bypass via a query string when accessing the API. |
| An issue was discovered in Electerm 1.3.22, allows attackers to execute arbitrary code via unverified request to electerms service. |
| In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to erase the backup secondary official image and write secondary backup unauthorized image. |
| All versions of the package github.com/greenpau/caddy-security are vulnerable to Improper Restriction of Excessive Authentication Attempts via the two-factor authentication (2FA). Although the application blocks the user after several failed attempts to provide 2FA codes, attackers can bypass this blocking mechanism by automating the application’s full multistep 2FA process. |
| An access control issue on TP-LInk Tapo C200 V1 devices allows physically proximate attackers to obtain root access by connecting to the UART pins, interrupting the boot process, and setting an init=/bin/sh value. |
| atune before 0.3-0.8 log in as a local user and run the curl command to access the local atune url interface to escalate the local privilege or modify any file. Authentication is not forcibly enabled in the default configuration. |
| Lexmark products through 2023-01-10 have Improper Control of Interaction Frequency. |
| ONLYOFFICE all versions as of 2021-11-08 is affected by Incorrect Access Control. An authentication bypass in the document editor allows attackers to edit documents without authentication. |
| HCL BigFix Mobile / Modern Client Management Admin and Config UI passwords can be brute-forced.
User should be locked out for multiple invalid attempts.
|