Export limit exceeded: 364448 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 46086 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (46086 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-42027 | 1 Rocketchat | 1 Rocket.chat | 2026-04-15 | 6.7 Medium |
| The E2EE password entropy generated by Rocket.Chat Mobile prior to version 4.5.1 is insufficient, allowing attackers to crack it if they have the appropriate time and resources. | ||||
| CVE-2025-41726 | 1 Beckhoff | 4 Beckhoff.device.manager.xar, Mdp Package, Twincat and 1 more | 2026-04-15 | 8.8 High |
| A low privileged remote attacker can execute arbitrary code by sending specially crafted calls to the web service of the Device Manager or locally via an API and can cause integer overflows which then may lead to arbitrary code execution within privileged processes. | ||||
| CVE-2024-12212 | 2026-04-15 | 7.8 High | ||
| The vulnerability occurs in the parsing of CSP files. The issues result from the lack of proper validation of user-supplied data, which could allow reading past the end of allocated data structures, resulting in execution of arbitrary code. | ||||
| CVE-2024-41995 | 1 Ricoh Company Ltd | 1 Javatm Platform | 2026-04-15 | 7.5 High |
| Initialization of a resource with an insecure default vulnerability exists in JavaTM Platform Ver.12.89 and earlier. If this vulnerability is exploited, the product may be affected by some known TLS1.0 and TLS1.1 vulnerabilities. As for the specific products/models/versions of MFPs and printers that contain JavaTM Platform, see the information provided by the vendor. | ||||
| CVE-2024-41981 | 1 Siemens | 1 Simcenter Nastran | 2026-04-15 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2025-41707 | 1 Phoenix Contact | 4 Quint4-ups/24dc/24dc/10/eip, Quint4-ups/24dc/24dc/20/eip, Quint4-ups/24dc/24dc/40/eip and 1 more | 2026-04-15 | 5.3 Medium |
| The websocket handler is vulnerable to a denial of service condition. An unauthenticated remote attacker can send a crafted websocket message to trigger the issue without affecting the core functionality. | ||||
| CVE-2025-8731 | 1 Trendnet | 3 Ti-g160i, Ti-pg102i, Tpl-430ap | 2026-04-15 | 9.8 Critical |
| A vulnerability was identified in TRENDnet TI-G160i, TI-PG102i and TPL-430AP up to 20250724. This affects an unknown part of the component SSH Service. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The vendor explains: "For product TI-PG102i and TI-G160i, by default, the product's remote management options are all disabled. The root account is for troubleshooting purpose and the password is encrypted. However, we will remove the root account from the next firmware release. For product TPL-430AP, the initial setup process requires user to set the password for the management GUI. Once that was done, the default password will be invalid." | ||||
| CVE-2024-41928 | 1 Freebsd | 1 Freebsd | 2026-04-15 | 8.4 High |
| Malicious software running in a guest VM can exploit the buffer overflow to achieve code execution on the host in the bhyve userspace process, which typically runs as root. Note that bhyve runs in a Capsicum sandbox, so malicious code is constrained by the capabilities available to the bhyve process. | ||||
| CVE-2024-41908 | 1 Siemens | 6 Nx 1957 Firmware, Nx 1961 Firmware, Nx 1965 Firmware and 3 more | 2026-04-15 | 7.8 High |
| A vulnerability has been identified in NX (All versions < V2406.3000). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process. | ||||
| CVE-2025-41706 | 1 Phoenix Contact | 4 Quint4-ups/24dc/24dc/10/eip, Quint4-ups/24dc/24dc/20/eip, Quint4-ups/24dc/24dc/40/eip and 1 more | 2026-04-15 | 5.3 Medium |
| The webserver is vulnerable to a denial of service condition. An unauthenticated remote attacker can craft a special GET request with an over-long content-length to trigger the issue without affecting the core functionality. | ||||
| CVE-2024-41184 | 2 Acassen, Redhat | 3 Keepalived, Ceph Storage, Enterprise Linux | 2026-04-15 | 9.8 Critical |
| In the vrrp_ipsets_handler handler (fglobal_parser.c) of keepalived through 2.3.1, an integer overflow can occur. NOTE: this CVE Record might not be worthwhile because an empty ipset name must be configured by the user. | ||||
| CVE-2025-5514 | 1 Mitsubishi Electric | 1 Melsec Iq-f Series | 2026-04-15 | 5.3 Medium |
| Improper Handling of Length Parameter Inconsistency vulnerability in web server function on Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to delay the processing of the web server function and prevent legitimate users from utilizing the web server function, by sending a specially crafted HTTP request. | ||||
| CVE-2024-12286 | 2026-04-15 | 9.8 Critical | ||
| MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials. | ||||
| CVE-2025-8736 | 1 Gnu | 1 Cflow | 2026-04-15 | 5.3 Medium |
| A vulnerability, which was classified as critical, has been found in GNU cflow up to 1.8. Affected by this issue is the function yylex of the file c.c of the component Lexer. The manipulation leads to buffer overflow. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-61672 | 1 Element-hq | 1 Synapse | 2026-04-15 | 5.4 Medium |
| Synapse is an open source Matrix homeserver implementation. Lack of validation for device keys in Synapse before 1.138.3 and in Synapse 1.139.0 allow an attacker registered on the victim homeserver to degrade federation functionality, unpredictably breaking outbound federation to other homeservers. The issue is patched in Synapse 1.138.3, 1.138.4, 1.139.1, and 1.139.2. Note that even though 1.138.3 and 1.139.1 fix the vulnerability, they inadvertently introduced an unrelated regression. For this reason, the maintainers of Synapse recommend skipping these releases and upgrading straight to 1.138.4 and 1.139.2. | ||||
| CVE-2024-1275 | 2026-04-15 | N/A | ||
| Use of Default Cryptographic Key vulnerability in Baxter Welch Allyn Connex Spot Monitor may allow Configuration/Environment Manipulation.This issue affects Welch Allyn Connex Spot Monitor in all versions prior to 1.52. | ||||
| CVE-2024-12805 | 2026-04-15 | 7.2 High | ||
| A post-authentication format string vulnerability in SonicOS management allows a remote attacker to crash a firewall and potentially leads to code execution. | ||||
| CVE-2024-40086 | 1 Viloliving | 1 Vilo 5 Mesh Wifi System Firmware | 2026-04-15 | 9.6 Critical |
| A Buffer Overflow vulnerability in the local_app_set_router_wifi_SSID_PWD function of Vilo 5 Mesh WiFi System <= 5.16.1.33 allows remote, unauthenticated attackers to execute arbitrary code via a password field larger than 64 bytes in length. | ||||
| CVE-2024-40085 | 1 Viloliving | 1 Vilo 5 Mesh Wifi System Firmware | 2026-04-15 | 9.6 Critical |
| A Buffer Overflow vulnerability in the local_app_set_router_wan function of Vilo 5 Mesh WiFi System <= 5.16.1.33 allows remote, unauthenticated attackers to execute arbitrary code via pppoe_username and pppoe_password fields being larger than 128 bytes in length. | ||||
| CVE-2023-52891 | 1 Siemens | 6 Simatic Energy Manager Basic, Simatic Energy Manager Pro, Simatic Ipc Diagbase and 3 more | 2026-04-15 | 5.3 Medium |
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. | ||||