Export limit exceeded: 46001 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 20403 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (20403 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-35186 1 Bytecodealliance 1 Wasmtime 2026-04-15 7.5 High
Wasmtime is a runtime for WebAssembly. From 25.0.0 to before 36.0.7, 42.0.2, and 43.0.1, Wasmtime's Winch compiler backend contains a bug where translating the table.grow operator causes the result to be incorrectly typed. For 32-bit tables this means that the result of the operator, internally in Winch, is tagged as a 64-bit value instead of a 32-bit value. This invalid internal representation of Winch's compiler state compounds into further issues depending on how the value is consumed. The primary consequence of this bug is that bytes in the host's address space can be stored/read from. This is only applicable to the 16 bytes before linear memory, however, as the only significant return value of table.grow that can be misinterpreted is -1. The bytes before linear memory are, by default, unmapped memory. Wasmtime will detect this fault and abort the process, however, because wasm should not be able to access these bytes. Overall this this bug in Winch represents a DoS vector by crashing the host process, a correctness issue within Winch, and a possible leak of up to 16-bytes before linear memory. Wasmtime's default compiler is Cranelift, not Winch, and Wasmtime's default settings are to place guard pages before linear memory. This means that Wasmtime's default configuration is not affected by this issue, and when explicitly choosing Winch Wasmtime's otherwise default configuration leads to a DoS. Disabling guard pages before linear memory is required to possibly leak up to 16-bytes of host data. This vulnerability is fixed in 36.0.7, 42.0.2, and 43.0.1.
CVE-2026-35195 1 Bytecodealliance 1 Wasmtime 2026-04-15 5.4 Medium
Wasmtime is a runtime for WebAssembly. Prior to 24.0.7, 36.0.7, 42.0.2, and 43.0.1, Wasmtime's implementation of transcoding strings between components contains a bug where the return value of a guest component's realloc is not validated before the host attempts to write through the pointer. This enables a guest to cause the host to write arbitrary transcoded string bytes to an arbitrary location up to 4GiB away from the base of linear memory. These writes on the host could hit unmapped memory or could corrupt host data structures depending on Wasmtime's configuration. Wasmtime by default reserves 4GiB of virtual memory for a guest's linear memory meaning that this bug will by default on hosts cause the host to hit unmapped memory and abort the process due to an unhandled fault. Wasmtime can be configured, however, to reserve less memory for a guest and to remove all guard pages, so some configurations of Wasmtime may lead to corruption of data outside of a guest's linear memory, such as host data structures or other guests's linear memories. This vulnerability is fixed in 24.0.7, 36.0.7, 42.0.2, and 43.0.1.
CVE-2025-44635 2026-04-15 9.8 Critical
There are multiple unauthorized remote command execution vulnerabilities in the H3C ER2200G2, ERG2-450W, ERG2-1200W, ERG2-1350W, NR1200W series routers before ERG2AW-MNW100-R1117; H3C ER3100G2, ER3200G2, ER3260G2, ER5100G2, ER5200G2, ER6300G2, ER8300G2, ER8300G2-X series routers before ERHMG2-MNW100-R1126; GR3200, GR5200, GR8300 and other series routers before MiniGR1B0V100R018L50; GR-1800AX before MiniGRW1B0V100R009L50; GR-3000AX before SWBRW1A0V100R007L50; and GR-5400AX before SWBRW1B0V100R009L50. Attackers can bypass authentication by including specially crafted text in the request URL or message header, and then inject arbitrary malicious commands into some fields related to ACL access control list and user group functions and execute to obtain the highest ROOT privileges of remote devices, thereby completely taking over the remote target devices.
CVE-2024-52034 1 Myscada 2 Mypro Manager, Mypro Runtime 2026-04-15 10 Critical
An OS Command Injection vulnerability exists within myPRO Manager. A parameter within a command can be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands.
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-4230 1 Palo Alto Networks 1 Pan-os 2026-04-15 N/A
A command injection vulnerability in Palo Alto Networks PAN-OS® software enables an authenticated administrator to bypass system restrictions and run arbitrary commands as a root user. To be able to exploit this issue, the user must have access to the PAN-OS CLI. The security risk posed by this issue is significantly minimized when CLI access is restricted to a limited group of administrators. Cloud NGFW and Prisma® Access are not affected by this vulnerability.
CVE-2024-28748 1 Ifm 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware 2026-04-15 7.2 High
A remote attacker with high privileges may use a reading file function to inject OS commands.
CVE-2024-20289 2026-04-15 4.4 Medium
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, low-privileged, local attacker to execute arbitrary commands on the underlying operating system of an affected device.&nbsp; This vulnerability is due to insufficient validation of arguments for a specific CLI command. An attacker could exploit this vulnerability by including crafted input as the argument of the affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with the privileges of the currently logged-in user.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2025-46272 2026-04-15 9.1 Critical
WGS-80HPT-V2 and WGS-4215-8T2S are vulnerable to a command injection attack that could allow an unauthenticated attacker to execute OS commands on the host system.
CVE-2025-24480 2026-04-15 N/A
A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user.
CVE-2023-3939 2026-04-15 10 Critical
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in ZkTeco-based OEM devices allows OS Command Injection. Since all the found command implementations are executed from the superuser, their impact is the maximum possible. This issue affects ZkTeco-based OEM devices (ZkTeco ProFace X, Smartec ST-FR043, Smartec ST-FR041ME and possibly others) with the ZAM170-NF-1.8.25-7354-Ver1.0.0 and possibly other.
CVE-2025-59729 1 Ffmpeg 1 Ffmpeg 2026-04-15 6.8 Medium
When parsing the header for a DHAV file, there's an integer underflow in offset calculation that leads to reading the duration from before the start of the allocated buffer. If we load a DHAV file that is larger than MAX_DURATION_BUFFER_SIZE bytes (0x100000) for example 0x101000 bytes, then at [0] we have size = 0x101000. At [1] we have end_buffer_size = 0x100000, and at [2] we have end_buffer_pos = 0x1000. The loop then scans backwards through the buffer looking for the dhav tag; when it is found, we'll calculate end_pos based on a 32-bit offset read from the buffer. There is subsequently a check [3] that end_pos is within the section of the file that has been copied into end_buffer, but it only correctly handles the cases where end_pos is before the start of the file or after the section copied into end_buffer, and not the case where end_pos is within the the file, but before the section copied into end_buffer. If we provide such an offset, (end_pos - end_buffer_pos) can underflow, resulting in the subsequent access at [4] occurring before the beginning of the allocation. We recommend upgrading to version 8.0 or beyond.
CVE-2025-27106 2026-04-15 8.8 High
binance-trading-bot is an automated Binance trading bot with trailing buy/sell strategy. Authenticated users of binance-trading-bot can achieve Remote Code Execution on the host system due to a command injection vulnerability in the `/restore` endpoint. The restore endpoint of binance-trading-bot is vulnerable to command injection via the `/restore` endpoint. The name of the uploaded file is passed to shell.exec without sanitization other than path normalization, resulting in Remote Code Execution. This may allow any authorized user to execute code in the context of the host machine. This issue has been addressed in version 0.0.100 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2025-34319 1 Totolink 2 N300rt, N300rt Firmware 2026-04-15 N/A
TOTOLINK N300RT wireless router firmware versions prior to V3.4.0-B20250430 (discovered in V2.1.8-B20201030.1539) contain an OS command injection vulnerability in the Boa formWsc handling functionality. An unauthenticated attacker can send specially crafted requests to trigger command execution via the targetAPSsid request parameter.
CVE-2023-49614 2026-04-15 5.7 Medium
Out of bounds write in firmware for some Intel(R) FPGA products before version 2.9.0 may allow escalation of privilege and information disclosure.
CVE-2025-55048 2026-04-15 9.8 Critical
Multiple CWE-78