| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In Octopus Deploy before 2020.1.5, for customers running on-premises Active Directory linked to their Octopus server, an authenticated user can leverage a bug to escalate privileges. |
| In Rancher 2.x before 2.6.13 and 2.7.x before 2.7.4, an incorrectly applied authorization check allows users who have certain access to a namespace to move that namespace to a different project. |
| The Library API in buger jsonparser through 2019-12-04 allows attackers to cause a denial of service (infinite loop) via a Delete call. |
| FasterXML jackson-databind 2.x before 2.9.10.4 mishandles the interaction between serialization gadgets and typing, related to org.apache.aries.transaction.jms.internal.XaPooledConnectionFactory (aka aries.transaction.jms). |
| The Canon Oce Colorwave 500 4.0.0.0 printer's web application is missing any form of CSRF protections. This is a system-wide issue. An attacker could perform administrative actions by targeting a logged-in administrative user. NOTE: this is fixed in the latest version. |
| The web application exposed by the Canon Oce Colorwave 500 4.0.0.0 printer is vulnerable to authentication bypass on the page /home.jsp. An unauthenticated attacker able to connect to the device's web interface can get a copy of the documents uploaded by any users. NOTE: this is fixed in the latest version. |
| The IGMP component in VxWorks 6.8.3 IPNET CVE patches created in 2019 has a NULL Pointer Dereference. |
| The JSON gem through 2.2.0 for Ruby, as used in Ruby 2.4 through 2.4.9, 2.5 through 2.5.7, and 2.6 through 2.6.5, has an Unsafe Object Creation Vulnerability. This is quite similar to CVE-2013-0269, but does not rely on poor garbage-collection behavior within Ruby. Specifically, use of JSON parsing methods can lead to creation of a malicious object within the interpreter, with adverse effects that are application-dependent. |
| The Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.9.1 contains a vulnerability in the ITM web console's ImportAlertRules feature. The vulnerability allows a remote attacker (with admin or config-admin privileges in the console) to execute arbitrary code with local administrator privileges. The vulnerability is caused by improper deserialization. |
| DevActSvc.exe in ASUS Device Activation before 1.0.7.0 for Windows 10 notebooks and PCs could lead to unsigned code execution with no additional restrictions when a user puts an application at a particular path with a particular file name. |
| Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small. |
| The affected product lacks proper validation of user-supplied data, which can result in deserialization of untrusted data on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information. |
| In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic. |
| An unprotected logging route may allow an attacker to write endless log statements into the database without space limits or authentication. This results in consuming the entire available hard-disk space on the Ignition 8 Gateway (versions prior to 8.0.10), causing a denial-of-service condition. |
| Eaton HMiSoft VU3 (HMIVU3 runtime not impacted), Version 3.00.23 and prior, however, the HMIVU runtimes are not impacted by these issues. A specially crafted input file could cause a buffer overflow when loaded by the affected product. |
| WebAccess/NMS (versions prior to 3.0.2) does not sanitize XML input. Specially crafted XML input could allow an attacker to read sensitive files. |
| ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network. |
| Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to modify and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery. |
| In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code. |
| ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network. |